Combination IO Modules
8DI+8AI(16bits)+8DO Data Center Monitor Module
Item No.: M180T
This Data center monitor module offers a combination of 8CH Digital input(DI), 8CH Digital output(DO), and 8CH 16bit measurement resolution Analog input(AI) for an excellent functionality/price ratio.
Introduction
Features
Specifications
Download
Applications
Data Center Monitor Module
This Data center monitor module offers a combination of 8CH Digital input(DI), 8CH Digital output(DO), and 8CH 16bit measurement resolution Analog input(AI) for an excellent functionality/price ratio. The Remote I/O Modbus TCP comes with Ethernet port and RS-485 serial port. The Analog input of this Ethernet Remote I/O used for measuring voltage or current, and Digital input and Digital output used for monitoring environmental in Data Center.
8DI
Wet/Dry contact
High speed pulse
counting
High speed pulse
counting
8DO
SINK
High speed pulse
output
High speed pulse
output
8AI
0-20mA/4-20mA
0-5V/0-10V
16bit resolution
0-5V/0-10V
16bit resolution
Protocol
SNMP V1/V2
Modbus RTU/Modbus TCP
MQTT
Modbus RTU/Modbus TCP
MQTT
| Item | Parameter | Description |
| Power | Input voltage |
|
| Power consumption | Typical standby power consumption: ≤ 2W | |
| Power Output |
|
|
| Protection | Reverse wiring prevention; ESD Air: 15KV; Surge: 4KV |
|
| Ethernet | Specification | 1 x RJ45, 10M/100Mbps |
| Protection | ESD contact: 8KV, Surge: 4KV(10/1000us) | |
| Protocol | Modbus RTU, Modbus TCP, MQTT | |
| Serial port | QTY | 1 x RS485 |
| Baud Rate | 2400, 4800, 9600, 14400, 19200, 38400, 57600, 115200, 128000 | |
| Data Bit | 7, 8 | |
| Parity Bit | None, Even, Odd | |
| Stop Bit | 0.5, 1, 1.5, 2 | |
| Protocol | Modbus RTU(slave), Modbus RTU(master) | |
| Protection | ESD contact: 8KV Surge: 4KV(8/20us) | |
| Digital input | QTY | 16 channel(Max) |
| Type | Support Wet contact(NPN, PNP) and Dry contact. Default: Wet contact |
|
| Dry contact |
|
|
| Wet contact |
|
|
| Others | Support DIN1 as a pulse counter: Support high-speed pulse and low-speed pulse mode, default high-speed pulse frequency is up to 700KHz, and the optional low-speed pulse frequency is up to 10KHz. Support DIN2~DIN12 as low-speed pulse counter: The anti-jitter time can be set from 1~2000ms, default is 1ms, and the corresponding pulse frequency is up to 1KHz. |
|
| Isolated protection | 2KVrms | |
| Sampling Rate | 100Hz | |
| Digital output | QTY | 16 channels(Max) |
| Type | SINK | |
| Capacity | 500mA per contact | |
| Overvoltage protection | 50VDC | |
| Pulse output | The first DO supports pulse output, pulse output frequency: 10Hz~300KHz | |
| Analog input (16bit) | QTY |
|
| Method | Differential input | |
| Type | 4-20mA, 0-20mA, 0-5V, 0-10V | |
| Resolution |
|
|
| Accuracy |
|
|
| Input Impedance |
|
|
| Software | Protocols | IPV4, TCP/UDP, DNS, Modbus RTU, Modbus TCP, MQTT |
| Protocol conversion | Support Modbus TCP and RTU protocol conversion Support Modbus RTU to MQTT and Modbus TCP to MQTT |
|
| Indicator light | Power, Link, RS485_RXD, RS485_TXD, IO status | |
| User configuration | PC software configuration, support WIN XP, WIN 7, WIN 8, WIN 10 | |
| Map data | bool: 300 16bit: 300 |
|
| Login Package | Support custom login package | |
| Heartbeat Package | Support custom heartbeat package | |
| Environment | Working | -20~70°C, 5~95%RH |
| Storage | -40~85°C, 5~95%RH | |
| Others | Case | Metal |
| Dimension | 82mm×40mm×100mm | |
| Protection grade | IP30 | |
| Net Weight | 450g | |
| Installation | DIN rail mounted, Wall-mounted |
Description
Data Center Monitor Module
This Data center monitor module offers a combination of 8CH Digital input(DI), 8CH Digital output(DO), and 8CH 16bit measurement resolution Analog input(AI) for an excellent functionality/price ratio. The Remote I/O Modbus TCP comes with Ethernet port and RS-485 serial port. The Analog input of this Ethernet Remote I/O used for measuring voltage or current, and Digital input and Digital output used for monitoring environmental in Data Center.
8DI
Wet/Dry contact
High speed pulse
counting
High speed pulse
counting
8DO
SINK
High speed pulse
output
High speed pulse
output
8AI
0-20mA/4-20mA
0-5V/0-10V
16bit resolution
0-5V/0-10V
16bit resolution
Protocol
SNMP V1/V2
Modbus RTU/Modbus TCP
MQTT
Modbus RTU/Modbus TCP
MQTT
introduction
Features
Specifications
| Item | Parameter | Description |
| Power | Input voltage |
|
| Power consumption | Typical standby power consumption: ≤ 2W | |
| Power Output |
|
|
| Protection | Reverse wiring prevention; ESD Air: 15KV; Surge: 4KV |
|
| Ethernet | Specification | 1 x RJ45, 10M/100Mbps |
| Protection | ESD contact: 8KV, Surge: 4KV(10/1000us) | |
| Protocol | Modbus RTU, Modbus TCP, MQTT | |
| Serial port | QTY | 1 x RS485 |
| Baud Rate | 2400, 4800, 9600, 14400, 19200, 38400, 57600, 115200, 128000 | |
| Data Bit | 7, 8 | |
| Parity Bit | None, Even, Odd | |
| Stop Bit | 0.5, 1, 1.5, 2 | |
| Protocol | Modbus RTU(slave), Modbus RTU(master) | |
| Protection | ESD contact: 8KV Surge: 4KV(8/20us) | |
| Digital input | QTY | 16 channel(Max) |
| Type | Support Wet contact(NPN, PNP) and Dry contact. Default: Wet contact |
|
| Dry contact |
|
|
| Wet contact |
|
|
| Others | Support DIN1 as a pulse counter: Support high-speed pulse and low-speed pulse mode, default high-speed pulse frequency is up to 700KHz, and the optional low-speed pulse frequency is up to 10KHz. Support DIN2~DIN12 as low-speed pulse counter: The anti-jitter time can be set from 1~2000ms, default is 1ms, and the corresponding pulse frequency is up to 1KHz. |
|
| Isolated protection | 2KVrms | |
| Sampling Rate | 100Hz | |
| Digital output | QTY | 16 channels(Max) |
| Type | SINK | |
| Capacity | 500mA per contact | |
| Overvoltage protection | 50VDC | |
| Pulse output | The first DO supports pulse output, pulse output frequency: 10Hz~300KHz | |
| Analog input (16bit) | QTY |
|
| Method | Differential input | |
| Type | 4-20mA, 0-20mA, 0-5V, 0-10V | |
| Resolution |
|
|
| Accuracy |
|
|
| Input Impedance |
|
|
| Software | Protocols | IPV4, TCP/UDP, DNS, Modbus RTU, Modbus TCP, MQTT |
| Protocol conversion | Support Modbus TCP and RTU protocol conversion Support Modbus RTU to MQTT and Modbus TCP to MQTT |
|
| Indicator light | Power, Link, RS485_RXD, RS485_TXD, IO status | |
| User configuration | PC software configuration, support WIN XP, WIN 7, WIN 8, WIN 10 | |
| Map data | bool: 300 16bit: 300 |
|
| Login Package | Support custom login package | |
| Heartbeat Package | Support custom heartbeat package | |
| Environment | Working | -20~70°C, 5~95%RH |
| Storage | -40~85°C, 5~95%RH | |
| Others | Case | Metal |
| Dimension | 82mm×40mm×100mm | |
| Protection grade | IP30 | |
| Net Weight | 450g | |
| Installation | DIN rail mounted, Wall-mounted |
Download
Applications