Combination IO Modules
4DI+4DO Remote IO Module
Item No.: M110
M110 Industrial Remote I/O Module provides 4 optical-isolated digital inputs, supports Max. 700KHz high speed pulse counter, 4 digital outputs, supports 10Hz~300Khz high speed pulse output or relay outputs.
Introduction
Features
Specifications
Download
Applications
Digital Input/Output Modules
The BLIIoT's wide range of digital I/O modules guarantees the right module for diverse applications.
The input/output module M110 is used for controlling digital consumer like contactors, relays, pneumatic and hydraulic valves, as well as for reading digital signals of sensors or detectors.
The Digital I/O M110 comes with 4 digital inputs, 4 digital outputs, and Modbus I/O, Ethernet port.
The input/output module M110 is used for controlling digital consumer like contactors, relays, pneumatic and hydraulic valves, as well as for reading digital signals of sensors or detectors.
The Digital I/O M110 comes with 4 digital inputs, 4 digital outputs, and Modbus I/O, Ethernet port.
4DI
Wet/Dry contact
High speed pulse
counting
High speed pulse
counting
4DO
SINK
High speed pulse
output
High speed pulse
output
Protocol
MQTT
SNMP V1/V2
Modbus RTU/Modbus TCP
SNMP V1/V2
Modbus RTU/Modbus TCP
Interface
Ethernet port
RS-485 Serial port
RS-485 Serial port
| Item | Parameter | Description |
| Power | Input voltage |
|
| Power consumption | Typical standby power consumption: ≤ 2W | |
| Power Output |
|
|
| Protection | Reverse wiring prevention; ESD Air: 15KV; Surge: 4KV |
|
| Ethernet | Specification | 1 x RJ45, 10M/100Mbps |
| Protection | ESD contact: 8KV, Surge: 4KV(10/1000us) | |
| Protocol | Modbus RTU, Modbus TCP, MQTT | |
| Serial port | QTY | 1 x RS485 |
| Baud Rate | 2400, 4800, 9600, 14400, 19200, 38400, 57600, 115200, 128000 | |
| Data Bit | 7, 8 | |
| Parity Bit | None, Even, Odd | |
| Stop Bit | 0.5, 1, 1.5, 2 | |
| Protocol | Modbus RTU(slave), Modbus RTU(master) | |
| Protection | ESD contact: 8KV Surge: 4KV(8/20us) | |
| Digital input | QTY | 16 channel(Max) |
| Type | Support Wet contact(NPN, PNP) and Dry contact. Default: Wet contact |
|
| Dry contact |
|
|
| Wet contact |
|
|
| Others | Support DIN1 as a pulse counter: Support high-speed pulse and low-speed pulse mode, default high-speed pulse frequency is up to 700KHz, and the optional low-speed pulse frequency is up to 10KHz. Support DIN2~DIN12 as low-speed pulse counter: The anti-jitter time can be set from 1~2000ms, default is 1ms, and the corresponding pulse frequency is up to 1KHz. |
|
| Isolated protection | 2KVrms | |
| Sampling Rate | 100Hz | |
| Digital output | QTY | 16 channels(Max) |
| Type | SINK | |
| Capacity | 500mA per contact | |
| Overvoltage protection | 50VDC | |
| Pulse output | The first DO supports pulse output, pulse output frequency: 10Hz~300KHz | |
| Software | Protocols | IPV4, TCP/UDP, DNS, Modbus RTU, Modbus TCP, MQTT |
| Protocol conversion | Support Modbus TCP and RTU protocol conversion Support Modbus RTU to MQTT and Modbus TCP to MQTT |
|
| Indicator light | Power, Link, RS485_RXD, RS485_TXD, IO status | |
| User configuration | PC software configuration, support WIN XP, WIN 7, WIN 8, WIN 10 | |
| Map data | bool: 300 16bit: 300 |
|
| Login Package | Support custom login package | |
| Heartbeat Package | Support custom heartbeat package | |
| Environment | Working | -20~70°C, 5~95%RH |
| Storage | -40~85°C, 5~95%RH | |
| Others | Case | Metal |
| Dimension | 82mm×40mm×100mm | |
| Protection grade | IP30 | |
| Net Weight | 450g | |
| Installation | DIN rail mounted, Wall-mounted |
Description
Digital Input/Output Modules
The BLIIoT's wide range of digital I/O modules guarantees the right module for diverse applications.
The input/output module M110 is used for controlling digital consumer like contactors, relays, pneumatic and hydraulic valves, as well as for reading digital signals of sensors or detectors.
The Digital I/O M110 comes with 4 digital inputs, 4 digital outputs, and Modbus I/O, Ethernet port.
The input/output module M110 is used for controlling digital consumer like contactors, relays, pneumatic and hydraulic valves, as well as for reading digital signals of sensors or detectors.
The Digital I/O M110 comes with 4 digital inputs, 4 digital outputs, and Modbus I/O, Ethernet port.
4DI
Wet/Dry contact
High speed pulse
counting
High speed pulse
counting
4DO
SINK
High speed pulse
output
High speed pulse
output
Protocol
MQTT
SNMP V1/V2
Modbus RTU/Modbus TCP
SNMP V1/V2
Modbus RTU/Modbus TCP
Interface
Ethernet port
RS-485 Serial port
RS-485 Serial port
introduction
Features
Specifications
| Item | Parameter | Description |
| Power | Input voltage |
|
| Power consumption | Typical standby power consumption: ≤ 2W | |
| Power Output |
|
|
| Protection | Reverse wiring prevention; ESD Air: 15KV; Surge: 4KV |
|
| Ethernet | Specification | 1 x RJ45, 10M/100Mbps |
| Protection | ESD contact: 8KV, Surge: 4KV(10/1000us) | |
| Protocol | Modbus RTU, Modbus TCP, MQTT | |
| Serial port | QTY | 1 x RS485 |
| Baud Rate | 2400, 4800, 9600, 14400, 19200, 38400, 57600, 115200, 128000 | |
| Data Bit | 7, 8 | |
| Parity Bit | None, Even, Odd | |
| Stop Bit | 0.5, 1, 1.5, 2 | |
| Protocol | Modbus RTU(slave), Modbus RTU(master) | |
| Protection | ESD contact: 8KV Surge: 4KV(8/20us) | |
| Digital input | QTY | 16 channel(Max) |
| Type | Support Wet contact(NPN, PNP) and Dry contact. Default: Wet contact |
|
| Dry contact |
|
|
| Wet contact |
|
|
| Others | Support DIN1 as a pulse counter: Support high-speed pulse and low-speed pulse mode, default high-speed pulse frequency is up to 700KHz, and the optional low-speed pulse frequency is up to 10KHz. Support DIN2~DIN12 as low-speed pulse counter: The anti-jitter time can be set from 1~2000ms, default is 1ms, and the corresponding pulse frequency is up to 1KHz. |
|
| Isolated protection | 2KVrms | |
| Sampling Rate | 100Hz | |
| Digital output | QTY | 16 channels(Max) |
| Type | SINK | |
| Capacity | 500mA per contact | |
| Overvoltage protection | 50VDC | |
| Pulse output | The first DO supports pulse output, pulse output frequency: 10Hz~300KHz | |
| Software | Protocols | IPV4, TCP/UDP, DNS, Modbus RTU, Modbus TCP, MQTT |
| Protocol conversion | Support Modbus TCP and RTU protocol conversion Support Modbus RTU to MQTT and Modbus TCP to MQTT |
|
| Indicator light | Power, Link, RS485_RXD, RS485_TXD, IO status | |
| User configuration | PC software configuration, support WIN XP, WIN 7, WIN 8, WIN 10 | |
| Map data | bool: 300 16bit: 300 |
|
| Login Package | Support custom login package | |
| Heartbeat Package | Support custom heartbeat package | |
| Environment | Working | -20~70°C, 5~95%RH |
| Storage | -40~85°C, 5~95%RH | |
| Others | Case | Metal |
| Dimension | 82mm×40mm×100mm | |
| Protection grade | IP30 | |
| Net Weight | 450g | |
| Installation | DIN rail mounted, Wall-mounted |
Download
Applications